Tightness and strength indicators of concrete pipes.

Nominal diameter: DN 150 mm, maximum load strength: 40.5 kN/m, strength class: 270 kN/m water resistance: when exposed to internal pressure at a value of 50 kPa(at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe. Strength of the longitudinal bending moment: the dimensions are sufficient, durability: the normal place of use is suitable, taking into account the environmental conditions, durability of connections: proven in accordance with method 4, which is usually used for wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.


 

Nominal diameter: DN 200 mm, maximum load: 52 kN/m, strength class: 260 kN/m water resistance: when exposed to internal pressure at a value of 50 kPa (at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe . Strength of the longitudinal bending moment: dimensions are sufficient, durability: the normal place of use is suitable, taking into account the environmental conditions, durability of connections: proven in accordance with method 2 (calculation method), which is usually used for the transfer of wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.


 

Nominal diameter: DN 300 mm, maximum load strength: 51 kN/m, strength class: 170 kN/m water resistance: when exposed to internal pressure at a value of 50 kPa (at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe. Strength of the longitudinal bending moment: the dimensions are sufficient, durability: the location is suitable for use taking into account environmental conditions, durability of connections: proven in accordance with method 2 (calculation method), which is usually used for the transfer of wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.


 

Nominal diameter: DN 400 mm, maximum load strength: 52 kN/m, strength class: 130 kN/m water resistance: when exposed to internal pressure at a value of 50 kPa (at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe. Strength of the longitudinal bending moment: the dimensions are sufficient, durability: the location is suitable for use with regard to environmental conditions, durability of connections: proven according to method 2 (calculation method), which is usually used for the transfer of wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.


 

Nominal diameter: DN 500 mm, maximum load: 42.5 kN/m, strength class: 85 kN/m water resistance: when exposed to internal pressure at a value of 50 kPa (at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe. Strength of the longitudinal bending moment: the dimensions are sufficient, durability: the location is suitable for use with regard to environmental conditions, durability of connections: proven according to method 2 (calculation method), which is usually used for the transfer of wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.


 

Nominal diameter: DN 600 mm, maximum load strength: 45 kN/m, strength class: 75 kN/m water seal: when exposed to internal pressure at a value of 50 kPa (at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe. Strength of the longitudinal bending moment: the dimensions are sufficient, durability: the location is suitable for use taking into account the environmental impact, durability of connections: proven according to method 2 (calculation method), which is usually used for the transfer of wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.

Hermiticity and strength of reinforced concrete pipes.

 

Nominal diameter: DN 800 mm, maximum load strength: 64 kN/m, strength class: 80 kN/m water Resistance: no leakage at the joint and block under the influence of an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal application suitable for environmental conditions, durability of connections: used for the transfer of waste, rain and surface water, usually in underground pipelines tested according to method 2 (calculation method). Pre-cast concrete pipe with non-mountable round seal, equipped.

 

Nominal diameter: DN 1000 mm, maximum load: 80 kN/m, strength class: 80 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal application suitable for environmental conditions, durability of connections: used for the transfer of waste , rain and surface water, usually in underground pipelines tested according to method 2 (calculation method). Pre-cast concrete pipe with non-mountable round seal, equipped.

 

Nominal diameter: DN 1200 mm, maximum load strength: 96 kN/m, strength class: 80 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal application suitable for environmental conditions, durability of connections: used for the transfer of waste , rain and surface water, usually in underground pipelines tested according to method 2 (calculation method). Pre-cast concrete pipe with non-mountable round seal, equipped.

 

Nominal diameter: DN 1400 mm, Maximum load strength: 112 kN/m, strength class: 80 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bend: sufficient size durability: normal operating conditions with consideration for environmental impact: according to method 4, for drainage of rainwater and surface water in underground pipelines. Pre-cast concrete pipe with non-mountable round seal, equipped with (K). g. 03. 06. 2008)

 

Nominal diameter: DN 1600 mm, peak load strength: 96 kN/m, strength class: 60 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal application suitable for environmental conditions, durability of connections: used for the transfer of waste , rain and surface water, usually in underground pipelines tested according to method 4 (calculation method). Pre-cast concrete pipe with non-mountable round seal, equipped.

(K). G. 03 . 06 . 2008)

TIGHTNESS AND STRENGTH CHARACTERISTICS OF INTEGRATED SEALED CONCRETE PIPES.

Nominal diameter: DN 200 mm, maximum load Strength: 44 kN/m, strength class: 220 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal Flexural strength: sufficient dimensions: normal application area suitable for environmental conditions, durability of connections: used for the transfer of waste , rain and surface water, usually in underground pipelines tested according to method 2 (experimental method). Pre-cast concrete pipe with a prefabricated seal of circular cross-section without reinforcement.

 

Nominal diameter: DN 300 mm, maximum load: 60 kN/m, strength class: 200 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending: sufficient dimensions, durability: the normal place of application is suitable for environmental conditions, durability of connections: used for the transfer of waste, rain and surface water, usually in underground pipelines tested according to method 2 (experimental method). Pre-cast concrete pipe with a prefabricated seal of circular cross-section without reinforcement.

 

Nominal diameter: DN 400 mm, load strength: 52 kN/m, strength class: 130 kN/m water Resistance: no leakage at the joint and block under the influence of an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal application suitable for environmental conditions, durability of connections: used for the transfer of waste , rain and surface water, usually in underground pipelines tested according to method 2 (experimental method). Pre-cast concrete pipe with a prefabricated seal of circular cross-section without reinforcement.

 

Nominal diameter: DN 500 mm, maximum load strength: 47.5 kN/m, strength class: 95 kN/m water Resistance: no leakage at the joint and block at an internal pressure of 50 kPa (0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal application location suitable, taking into account environmental conditions, durability of connections: used for the transfer of waste, rain and surface water, usually in underground pipelines tested according to method 2 (experimental method). Pre-cast concrete pipe with a prefabricated seal of circular cross-section without reinforcement.

 

Nominal diameter: DN 600 mm, load strength: 54 kN/m, strength class: 90 kN/m water Resistance: no leakage at the joint and block under the influence of an internal pressure of 50 kPa(0.5 bar or about 5 meters of water). Longitudinal bending strength: sufficient dimensions, durability: normal use suitable, taking into account environmental conditions, durability of connections: for waste water drainage. according to method 2 (experimental method).

Indicators of tightness of reinforced concrete pipes.

Nominal diameter: DN 800 mm


 

Nominal diameter: DN 600 mm, maximum load strength: 45 kN/m, strength class: 75 kN/m water seal: when exposed to internal pressure at a value of 50 kPa (at a value of 0, 5 bar or about 5 meters of water), there is no leakage at the junction and in the pipe. Strength of the longitudinal bending moment: the dimensions are sufficient, durability: the location is suitable for use taking into account the environmental impact, durability of connections: proven according to method 2 (calculation method), which is usually used for the transfer of wastewater, rainwater and surface water in underground pipelines. Pre-treated concrete pipe with mounting seal, circular cross-section, without equipment.